Where:
Goto RE TECH to know more.
Ti = The theoretical uncontrolled arsenic emission factor for each glass type (i), g/kg (lb/ton).
Abi = Fraction by weight of elemental arsenic in the fresh batch for each glass type (I).
Wbi = Weight of fresh batch melted per unit weight of glass produced for each glass type (i), g/kg (lb/ton).
Aci = Fraction by weight of elemental arsenic in cullet for each glass type (i).
Wci = Weight of cullet melted per unit weight of glass produced for each glass type (i), g/kg (lb/ton).
Bgi = Weight of elemental arsenic per unit weight of glass produced for each glass type (i), g/kg (lb/ton).
Where:
Yi = Theoretical uncontrolled arsenic emission estimate for the 12-month period for each glass type, Mg/year (ton/year).
Ti = Theoretical uncontrolled arsenic emission factor for each type of glass (i) produced during the 12-month period as calculated in paragraph (c)(1) of this section, g/kg (lb/ton).
For more Arsenic Reduction Furnaceinformation, please contact us. We will provide professional answers.
Gi = Quantity of each arsenic-containing glass type (i) produced during the 12-month period, kg/yr (ton/yr).
K = conversion factor for unit consistency, 106 g/Mg (2,000 lb/ton).
Where:
U = Uncontrolled arsenic emission rate for the 12-month period, Mg/yr (ton/yr).
Ti = Theoretical uncontrolled arsenic emission factor for each type of glass (i) produced during the 12-month period as calculated in paragraph (c)(1) of this section, g/kg (lb/ton).
F = The correction factor calculated in paragraph (d)(4) of this section.
Gi = Quantity of each arsenic-containing glass type (i) produced during the 12-month period, kg/yr (ton/yr).
n = Number of arsenic-containing glass types produced during the 12-month period.
K = Conversion factor for unit consistency, 106 g/Mg (2,000 lb/ton).
Are you interested in learning more about Lead Recycling Plant? Contact us today to secure an expert consultation!