Electrical parameters
Accuracy
0.02%, 0.05%, 0.1%
Power supply
AC 180-265V, or 3×220/380V±15%, frequency 50/60Hz.
AC voltage output
Range(U1, U2, U3)
57.7V, 100V, 220V, 380V (max 480V)
Adjustment range
(0-120)%RG(1)
Adjustment fineness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
0.01%/120s
Distortion
0.3% (Non-capacitive load)
Output load
1500VA
Measuring accuracy
0.02%RG or 0.05% RG
AC Current output
Range(I1, I2, I3)
0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A, 120A
Adjustment range
(0-120)%RG
Adjustment fineness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
<0.01%/120s
Distortion
≤0.3% (Non-capacitive load)
Output load
1500VA
Accuracy
0.02%RG or 0.05% RG
Power output
Active power output stability
<0.01%RG/120s
Reactive power output stability
<0.02%RG/120s
Active power measuring accuracy
0.02%RG or 0.05% RG
Reactive power measuring accuracy
0.1%RG
Phase output
Output adjustment range
0°-359.999°
Output adjustment fineness
10, 1, 0.1, 0.01 as optional.
Resolution
0.01°
Accuracy
0.02° or 0.05°
Power factor
Adjustment range
-1 ~ 0 ~ 1
Resolution
0.0001
Measurement accuracy
0.0005
Frequency output
Adjustment range
40Hz-70Hz
Output adjustment fineness
5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution
0.001Hz
Accuracy
0.002Hz
Voltage/current/harmonic setting
Harmonic number
2-51times
Harmonic content
0-40%
Harmonic phase
0-359.99
Harmonic setting accuracy
(10%±0.1%)RD(2)
Power energy measurement error
Active power energy
0.02%RG or 0.05% RG
Reactive power energy
0.1%RG
Power pulse output
Power pulse type
active pulse, reactive pulse
Active power pulse output
5V, 10mA
Pulse output frequency
Max 50kHz
Power pulse input
Pulse constant set range
(1--599999999)/kwh
Energy pulse type
Support active and reactive pulse, the highest frequency power pulse input is 200KHz.
Meter position
Position
3, 6, 12, 20, 24, 40, 48pcs meter
Standard
Standard
IEC 62053-21,22,23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016;
EN 50470-1, EN 50470-2, EN-50470-3; IEC 61010;
Safety
Isolation protection
IEC 61010-1:2001
Measurement category
300V CAT III, 600V CAT II
Degree of protection
IP20
Declaration of conformity
CE & CNAS certified
Mechanical parameters
Dimensions (mm)
Cabinet size: 800 * 600 * 1850mm (L * W * H).
Bench size: 2400 * 760 * 1846mm (L * W * H).
Weight (kg)
About 235
Environmental conditions
Ambient temperature
0°C to +40°C
Relative humidity
35%-85%