by Ravi Jain, Bud Industries Inc.
Link to Rdekono
The design of enclosures to house networking servers, telecommunications equipment and components should be guided by a number of factors. For server racks, Servers, in particular, generate a great deal of heat, and an enclosure must be capable of dissipating the heat to ensure that the components deliver their expected life. For telecom distribution racks, cable management is most important.
Aside from heat dissipation, enclosures for networking systems should provide for easy access to the interior, facilitate assembly and mounting, and provide for wiring management. Here are some practical guidelines for selecting enclosures for networking equipment.
1. Server racks should have proper ventilation.
As noted, servers can generate a lot of heat, and the more servers used, the more heat generated. While networks consisting of just a few servers can be housed in standard cabinets and enclosures, systems with multiple or densely packed servers should be housed in special server racks. Such racks include ventilation slots on the front, sides, rear and top to promote maximum airflow around components.
To increase airflow, the enclosure should incorporate fans and blowers at strategic locations. Fan tray assemblies can be mounted directly below critical components to direct airflow against local hot spots and to prevent hot air from being trapped within the enclosure.
2. Choose networking enclosures based on your environment.
Local conditions may dictate the use of specially designed racks and enclosures. For example, seismic racks should be specified for earthquake prone areas. These racks conform to Telcordia (formerly Bellcore) #GR-63-CORE, Issue 1 and feature reinforced construction to provide seismic protection. In a factory, NEMA enclosures should be used to protect components from dust, moisture, airborne contaminants such as oil mist and metal shavings, and washdown. NEMA cabinets have door seals to prevent dust, water and other contaminants entry. However, care must be taken to specify the correct NEMA designation. For example, many users specify NEMA 12 enclosures thinking they provide more environmental protection than NEMA 4. In fact, the opposite is true.
For office settings, open racks are often sufficient. These racks are typically located in a separate room, and do not need protection from water or dust. The open rack configuration provides maximum airflow around components.
3. Network racks should have easy access to the interior.
Despite all best efforts, components do occasionally fail. In addition, networks often must be reconfigured to provide more capacity. Thus, the enclosure should be designed for easy access to the interior by incorporating removable doors, side panels and backs.
4. Properly assemble and mount your server rack.
The most time-consuming part of building a rack assembly is mounting the components. Some vendors ease this task and speed assembly by supplying mounting racks with pre-tapped holes. In addition, some servers require special adapters and mounting rails, so care must be taken to ensure that the servers fit the racks being considered.
5. Use cable management accessories to organize cables in your network enclosure.
Unorganized cables can significantly increase the time required to assemble equipment and make repairs. Therefore, the enclosure should provide sufficient space for routing of cable, and the vendor should have cable management accessories available. These parts not only simplify routing and repair, but also provide a neat appearance.
6. Pre-assembled racks for servers can be more cost-effective than standard enclosures.
Most vendors offer these modifications at little extra cost. Pre-assembly at the factory can provide a more cost-effective solution than standard enclosures.
7. Choose a vendor that can offer design support for custom server racks.
Work with a vendor who will accept your drawings and recommend cost-saving alternatives. In addition, choose vendors that offer a broad range of enclosure types and sizes, and accessories, so you can more exactly match your needs.
See more Bud Industries press releases.
Server racks and cabinets are fundamental parts of IT infrastructure. Think of them as the backbone of IT operations. Whether in an enterprise data center or a small server room, they house the technology most critical to keeping business running smoothly. As such, they need to be taken seriously during IT infrastructure or data center budget planning.
Choosing the right server rack or cabinet for your organization and environment can help protect your equipment, prepare you for future growth, save stress on IT teams when it comes to installation and maintenance, and increase overall operational efficiency. High-quality racks will have superior design and construction, and provide features that save time, enhance safety, and facilitate power and cooling management.
For more Custom Rack Enclosureinformation, please contact us. We will provide professional answers.
Rack or Cabinet?
Although the terminology is often used interchangeably, there are differences between racks and cabinets. The main one is, cabinets are enclosed and racks are open. Choosing between a rack or cabinet is a combination of preference and need. They both serve the same general purpose, holding and organizing IT equipment, but racks are often cheaper than cabinets and offer free airflow. However, they lack security and are exposed to the elements more than server cabinets. Some people prefer cabinets for appearance reasons as well. Being that they’re enclosed, cabinets can look more organized on the data center floor or server room than racks. There’s a lot more nuance to choosing, for example, 2-post racks vs. 4-post racks serve very different purposes, but this covers some of the basic considerations.
Material
Server racks are commonly made of steel due to its high strength and low cost. Because steel is subject to corrosion, some manufacturers use electrogalvanized steel with powder coating. Powder coating creates a durable, corrosion-resistant finish that eliminates corrosion concerns.
Construction
Folded sheet construction is often used for industrial racks because of its low cost and high static load capacity. However, it is not recommended for server racks due to the dynamic, changing nature of today’s data centers and IT environments. Tubular steel construction with continuous seam welding helps reduce the risk that racks and cabinets will buckle when they are moved. That said, it is still important to consider the rack’s static and dynamic load capacity as power density demands and equipment weight increase.
Operational Features
The design of the server rack has a big impact on IT and data center operations. The best server racks have removable side panels for ready access to equipment. Perforated doors help to maximize airflow while securing equipment. Numbered U positions assist in the creation of rack elevations and in the identification of equipment for asset databases and work orders. Preinstalled casters make it easy to move IT racks into position.
Make Sure the Size Is Right
Although racks and cabinets come in “standard” sizes and configurations, there are many variables to consider. Obviously, the rack should have sufficient capacity for the IT equipment with additional space for any anticipated expansion. It should allow easy access to the equipment for maintenance and troubleshooting and provide adequate airflow to dissipate heat generated by the equipment.
The interior height of a server cabinet and the height of rack-mounted IT equipment are measured in “rack units” equivalent to 1.75 inches (44.45mm). Server cabinets are commonly 42U, but a wide range of sizes are available on the market.
Most server racks and cabinets have an external width of 24 inches (roughly 600mm), but the depth can vary. Racks and cabinets designed for high-density environments often have an outside depth of 48 inches (roughly 1200 mm).
Other Features to Look For
The interior layout of the cabinet also affects access to the IT equipment. For example, PDU mounting rails that aren’t flush with the side panels can make it difficult to slide equipment out of the rack for maintenance. Similarly, cable management systems should be designed in such a way that they don’t impede access. Built-in cable management features make the best use of space and minimize the need to purchase and install additional components.
As rack densities increase, airflow and thermal management become more important to consider, especially for large-scale, high-volume deployments. Data center server racks need adequate ventilation, including integrated fans and perforated doors. IT teams should also ensure that blanking panels are installed over empty equipment bays and that there are no gaps between mounting rails and side panels. These steps prevent the mixing of chilled intake air and hot exhaust air. Enconnex offers roof brush panels capable of accommodating large 60A plugs without allowing conditioned air to pass through open gaps.
Quality Server Racks From Enconnex
Enconnex server racks and cabinets are constructed of solid steel to provide some of the best load ratings in the industry. Engineered to make equipment installation simple and efficient, our cabinets feature dual side panels, split rear doors, and adjustable equipment rails with number labeling on both sides. Matching locks on doors and panels provide physical security that’s easy to manage. High-efficiency perforated doors allow for maximum airflow while maintaining physical security.
If you’re looking for the best server racks, look no further than Enconnex. Let us help you select high-quality units that meet your design, operational, and budgetary requirements. Browse our racks and cabinets for sale today.
The company is the world’s best Subracks Electronic Packaging Systems supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.