Questions You Should Know about hydraulic check valves

14, Jul. 2025

 

The two key questions to select a hydraulic valve - LinkedIn

Know More. Grow More.

Huade Hydraulic are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.

By Matt Clift (Director of Global Product Management & Marketing)

In terms of variety of product options to choose from, hydraulic valves have some of the widest array of options to choose from. There are quite literally hundreds of different configurations possible!

However, it doesn’t need to be complex. In this article of our Know More, Grow More series, we will simplify the process and will present the two primary questions you need to ask when selecting a hydraulic valve.

As a reminder, for more information about selecting the right valve, or in fact any product in your drip irrigation system, make sure you check out Module 2 of Rivulis Knowledge Hub.

Selecting the right valve type may seem complex, but it becomes straightforward by answering two key questions:

  • What is the valve’s primary function?
  • How will the valve be operated or controlled?

Question 1: What is the Primary Function of the Valve?

The first question focuses on the primary function, or "what the valve does." There are nine different primary functions for hydraulic valve as follows:

  • Basic: A valve body without any accessories, often used by growers and dealers who wish to build their own valves. 

  • On/Off: This valve is either on or off, with no pressure regulation or flow control since there is no pilot. Ideal for simple in-field operation and small farms without automation.
  • Pressure Reducing (PR): Reduces downstream pressure for consistent water pressure, and subsequent uniformity in each block regardless of upstream pressure fluctuations. The majority of valves are PR valves in most irrigation systems.

  • Pressure Sustaining (PS): Maintains upstream pressure, important for components such as filters that require a minimum pressure for back-flush.
  • Pressure Reducing & Pressure Sustaining (PR/PS): Combines both functions, eliminating the need for two separate valves.
  • Electric Control: Controls valve opening through electric automation, allowing remote operation.
  • Quick Relief: Acts as a safety valve by relieving system pressure above a preset value. Unlike PR valves, quick relief valves are for quickly expelling excess pressure when spikes occur.
  • Flow Control: Restricts flow to a determined rate. These are different to PR valves as the valves restrict to a specific flow through differential pressure. An example of use is to restrict the flow of back-flush discharge from a media filter during flushing.
  • Level Control: Opens and closes valves based on set tank points, useful for maintaining storage water levels.

Question 2: How Will the Valve be Controlled?

We now know what the valve will do. The second question addresses how the valve will be operated. There are three main options:

  • Manual: Involves a ball valve for manual operation. Often remotely controlled valves will have a manual override added to the valve in addition.

  • Hydraulic: Utilizes water pressure transferred through a hydraulic tube to control the valve’s diaphragm via a hydraulic relay. 

  • Electric: Uses a solenoid where current through a wire creates a magnetic field that moves the piston.

By answering two questions above, you streamline the process of selecting the right hydraulic valve for your system.

Next Steps

Once you have determined the primary function and control method of your valve, the next steps involve specifying the valve's parameters and accessories:

  • Material: Choose between plastic or metal based on your application. Plastic valves are lighter, more economical, and corrosion-resistant. Metal valves are necessary for higher pressure and larger size applications.
  • Size: Choose the size based on the required flow and head loss. This is chosen according to the needs of your system’s hydraulic design.
  • Connection Type: Select the connection type according to your region (standard for your country) and application need (flange, thread, etc).
  • Pilots: Are chosen to the pressure regulating requirement of the hydraulic design and the system components.
  • Throttling: Controls how much a valve can open. It does not regulate pressure, i.e. it does not respond to pressure variations. It only puts a limit on how much the valve can open.
  • Solenoids: Are available in a wide range of variations, and your selection will depend upon your control system and valve application.

Dive deeper about hydraulic valve selection in the Valves Section on the Rivulis Knowledge Hub, or download Book 2 for the complete guide for drip irrigation component product selection.

Read more about Rivulis’s hydraulic valve product offering in the valve section on rivulis.com.

Please note. This article is provided as a high level overview only. It is important that you verify what is best for your specific application, including for design, installation, operation, and maintenance. For both personal and irrigation system protection and before use, it is important to read the relevant suppliers’ instructions (for non-Rivulis products such as pumps, chemicals, fertilizers, etc), to consult with applicable professionals, and to read the relevant section of the Rivulis Drip Guide/Knowledge Hub, particularly with respect to safety and handling information, and more detailed instructions for use.

80 – Guide to Check Valves for Fire Protection - Blog | QRFS.com

Pressure-activated check valves prevent contamination and flooding from water sources used in fire protection systems

A check valve is a device that permits the flow of semisolids, liquids, or gases in only one direction. Check valves, featured in systems ranging from residential plumbing to pharmaceutical production, often rely simply on changes in pressure to manage flows.

In this article, we’ll focus on check valves for fire protection, discussing how they work, the types of check valves, and their benefits in fire sprinkler systems. Additionally, we’ll help you understand what components you should look for when selecting a check valve and discuss how to maintain them.

Already know what you need? Feel free to go straight to our check valve product page and selection of grooved riser check valve trim kits.

How does a check valve for fire protection work?

Each fire sprinkler system needs a dependable source of water for immediate use in a fire emergency. Most systems use some combination of gravity tanks, municipal water supplies, and sometimes fire department connections to provide water to sprinkler heads. But while multiple potential water sources provide an extra layer of reliability to fire protection systems, they can also be problematic: drinkable water might be contaminated by water from a fire hydrant, or dirty water from fire sprinkler pipes might flow through nearby streets and into nearby drains. In many other applications, it’s simply important that water only goes one way for performance reasons. These include protecting equipment such as pumps and filters from backflow damage, stopping drainage in a fire sprinkler system with elevation changes, providing pressure relief in liquid or pneumatic applications, and more.

Check valves for fire protection prevent the unwanted reverse flow of water, known as backflow, from occurring. Many check valves feature a hinged clapper with a spring, which keeps the valve closed until the water flowing from some water source opens it. These clappers only open in one direction: when these flows reverse (or very nearly stop), the spring presses the clapper against a rubber seat, forming a water-tight seal.

Think of the water on either side of the clapper as the supply side (between the water source and the check valve) and the system side (between the check valve and the rest of the system). When a fire sprinkler head discharges, water is released, decreasing the pressure on the system side. Shortly after, the higher pressures from water stored or pumped from the supply side push open the clapper, and water flows through the system.

How does a check valve for fire protection prevent contamination of potable water?

When multiple water supplies serve the same fire sprinkler system, each must have a check valve.

From the Edition of NFPA 13

16.9.4.1 Where there is more than one source of water supply, a check valve shall be installed in each connection.

Check valves decide which source actually provides the system with a supply of water at a given moment. When multiple water sources are used simultaneously, only the check valve connected to the highest-pressure water source remains open. Imagine you have a system with three water sources at the following pressure ratings, expressed in pounds per square inch (PSI):

Active Water Sources Check Valve Status 100 PSI Fire Department Connection (FDC)
75 PSI Gravity Tank
50 PSI City Water
FDC, Gravity Tank, & City Open Closed Closed Gravity Tank & City Water Closed Open Closed City Water Only Closed Closed Open

(Note: these pressure levels are provided only as illustrations and are not meant to be taken as typical for these water sources.)

When water is supplied from all three sources, only the check valve leading to the fire department connection remains open. Why?

Of these three sources, the FDC delivers the highest water pressure. This supply pressurizes the water on the system side. This increased system-side pressure is greater than the 75 or 50 PSI on the supply side of the check valves connected to the other water sources and, as a result, their clappers close.

To continue with this example, if only the city water and the gravity tank supply water, the check valve to the 75-PSI gravity tank will open, while the city water’s check valve stays closed. Only when all other sources are exhausted or closed does the municipal water supply open the check valve and flow into the system.

What are the types of check valves for fire protection and their benefits?

There are four main types of check valves for fire protection:

Are you interested in learning more about hydraulic check valves? Contact us today to secure an expert consultation!

  • Alarm check valve
  • Swing check valve
  • Grooved check valve
  • Grooved shotgun riser check valve
  • Backflow preventers comprising multiple check valves

An alarm check valve consists of a spring, a valve clapper, and an alarm port. The alarm port can be used to direct water to a water motor alarm or an alarm pressure switch used to alert nearby personnel to the system’s activation or send a signal to a fire alarm control panel.

A swing check valve can act as an alarm check valve for a wet-pipe fire sprinkler system, but only when that valve can sound an alarm.

From the edition of NFPA 13

16.11.3 Waterflow Detection Devices.

16.11.3.1 Wet Pipe Systems.

The alarm apparatus for a wet pipe system shall consist of a listed alarm check valve or other listed waterflow detection alarm device with the necessary attachments required to give an alarm.

Typically, these alarms are sounded by flow switches, which send a signal to local alarms and/or the fire alarm control panel when water flows through system piping.

Grooved check valves are a type of swing check valve for use in systems that have grooved-connecting pipe ends. Many grooved check valves can be used in a vertical or horizontal orientation, allowing them to be used in various configurations with a fire department connection, bypass connection, gravity pressure tank, or pump discharge connection.

A grooved shotgun riser check valve is similar to a grooved check valve but includes pressure gauges to monitor the supply and system pressure. The shotgun configuration, which uses an electric water flow switch and an alarm bell, is only permitted in situations where a water motor alarm is not required. Shotgun riser check valves offer a more compact and economical alternative to an alarm check valve.

Finally, there are backflow preventers that are explicitly designed to prevent the contamination of water supplies. They use check valves and extra fail-safes to make absolutely sure water flows one way and doesn’t contaminate potable water supplies. You can read more about them in our other blog: “Backflow Preventer vs. Check Valve: What’s the Difference?”

Do check valves require periodic maintenance?

Yes, check valves require periodic inspections and maintenance. For this reason, NFPA 13 warns against burying check valves or positioning them in areas where they will be inaccessible.

From the Edition of NFPA 25

13.4.2 Check Valves

13.4.2.1 Inspection. Valves shall be inspected internally every 5 years to verify that all of the valve’s components operate correctly.

13.4.2.2 Maintenance. Internal components shall be cleaned, repaired, or replaced as necessary in accordance with the manufacturer’s instructions.

Alarm check valves and system riser check valves require more frequent inspections. Regular inspections help to verify that the clapper functions properly, that the valve seat is in good condition, and that there aren’t any visible signs of corrosion or blockages.

From the edition of NFPA 25

13.4.1.1* Alarm valves and system riser check valves shall be externally inspected quarterly and shall verify the following:

(1) The gauges indicate normal supply water pressure is being maintained.
(2) The valves and trim are free of physical damage.
(3) All valves are in the appropriate open or closed position.
(4) The retarding chamber or alarm drains are not leaking.
(5) Where applicable, the valve in the connection to the pressure-type contacts or water motor–operated alarm devices are either sealed, locked, or electrically supervised in the open position.

NFPA 25 also requires an inspection of alarm valves’ internal components every five years.

13.4.1.2* Alarm valves and their associated strainers, filters, and restriction orifices shall be inspected internally every 5 years unless tests indicate a greater frequency is necessary.

Maintenance should be performed by following the guidelines set by the manufacturer. Following an inspection, the manufacturer’s guidelines should also be used while returning the system to service.

What’s the best brand of check valve? What should I look for?

Every check valve installed on a fire protection system should be FM-approved and/or UL-listed. Listings certify that a check valve is designed to withstand the conditions it’ll be exposed to while in use. They’re also specifically required by NFPA for check valves on fire sprinkler FDCs and the alarm check valves used with wet-pipe fire sprinkler systems.

From the edition of NFPA 13

16.11.3 Waterflow Detection Devices.

16.11.3.1 Wet Pipe Systems.

The alarm apparatus for a wet pipe system shall consist of a listed alarm check valve or other listed waterflow detection alarm device with the necessary attachments required to give an alarm.

16.12.6 Valves.

16.12.6.1 A listed check valve shall be installed in each fire department connection and shall be located in an accessible location.

In addition, when you’re purchasing a check valve for fire protection, you should also consider:

  • The size and pressure ratings of your fire protection system
  • How easy and fast the check valve is to install
  • The quality and construction of the valve’s components

QRFS carries UL-listed and FM-approved grooved check valves for pipes ranging from 2 to 6 inches. All of our check valves feature a non-slamming, spring-loaded clapper that forms a water-tight seal against an EPDM synthetic rubber seat. With a durable ductile iron exterior and corrosion-resistant stainless steel clapper, these valves are built to last.

Any of these valves can be installed in a vertical or horizontal orientation. What’s more, each can be used as an alarm check valve with a shotgun riser check valve trim kit, available for every check valve we carry.

When you make a purchase from QRFS, you receive quality products at our competitive pricing. We begin processing your order the moment we receive it so we can provide you with the fastest standard delivery possible, generally reaching you in 2-3 business days.

View our selection of grooved, inline, and swing check valves, plus our inventory of grooved riser check valve trim kits.

Questions about this article or our grooved check valves? Call us at +1 (888) 361- or  .

The company is the world’s best hydraulic system relief valve supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.