What are the advantages of unloading valve?

02, Dec. 2024

 

Unloader Valves vs. Regulator Valves: What's the Difference?

The mechanics of many electric pump sprayers are pretty straightforward, but there are often questions surrounding whether to use an unloader vs. regulator valve in a pump system. This seemingly small component can make a major difference in your pump performance.

Huade Hydraulic contains other products and information you need, so please check it out.

Plunger pumps, like most positive displacement pumps, require a pressure regulating device in the high pressure discharge line. Without one, the pump will keep pumping until the pressure builds to dangerous levels resulting in a ruptured discharge line or a blown motor fuse. You can choose between a regulator or a pressure regulating unloader, but choosing to go without anything is unsafe and not an option.

So, should you use a regulator valve or an unloader valve? Like many things in life, the answer is, 'It depends.' It all comes down to your application and intended use. Here, we'll break down the difference between an unloader and a regulator to help you make the best choice.

Regulator Valve Explanation

What is a regulator valve? Pressure regulator valves maintain a set maximum pressure in a system as a result of bypassing fluid. The system pressure may be lower at different times as valves open and close, but the pressure will not exceed the maximum set pressure.

In general, regulator valves are less expensive and they're easier to design into a system. That's because they're simple devices that typically consist of a piston or ball held on a seat by the force of a spring. The force created by system pressure on one side of the piston needs to be greater than the spring force on the opposite side of the piston before the piston will begin to move and release fluid. The piston will move to release only the fluid necessary to maintain the system pressure.

Common uses of water pressure regulator valves include applications where low flow is required. Some examples include ultra-fine misters for greenhouses, evaporative cooling, and dust suppression. Pressure regulator valves are also used where precise application is required, as with disinfection sprayers and carpet extractors.

If you choose an unloader instead of a regulator valve, a build-up of pressure can occur between stops and starts and result in a burst of excess fluid at a higher PSI when the trigger is engaged. In the case of disinfection sprayers, it could result in inconsistent spray coverage, and a carpet extractor that uses an unloader instead of a regulator could end up with a puddle of excess water and cleaning solution on the floor.

Unloader Valve Explanation

What is an unloader valve? Pressure-regulating unloader valves provide the ability to control pressure similarly to regulators, but their special function is decreasing pump head pressure to very low PSI values when the valves are closed. This 'no load' pressure decreases wear on the pump and lowers energy consumption over time. Unloaders are more complex than regulators and have more moving parts, meaning they are more difficult to engineer into a system and can cost more.

These valves typically include a check valve in the discharge fitting that 'traps' pressure between a control valve, like a spray gun trigger, and the unloader. Inside the valve will be a piston and seat held down by a spring. The trapped pressure is greater than the spring force causing the piston to move and bypass fluid to flow. While this trapped pressure is maintained, the pump head pressure will be low. Once the valve is opened and the trapped pressure is released, the pump head pressure will return. It is very important with unloaders to have no leaks or loss of trapped fluid between the valve and unloader.

While no pump motor should be run continuously under bypass (letting go of the trigger for extended periods), an unloader valve can withstand longer bypass times and help mitigate overheating of a system, especially in high-pressure pumps. Continual bypass of fluids can cause the liquids to heat up or excess pressure to build up under high PSI if not 'unloaded.' Not only can certain fluids become dangerous at extreme temperatures, but the heat can damage rubber seals and other internal parts.

By far, the most common use is as a pressure washer unloader valve. They're also found in irrigation systems, car washes, and other high-pressure applications that may require starting and stopping but aren't too concerned about precise spray patterns. Unloaders may malfunction and pulsate if the flow rate is too low because the internal valve mechanism ends up shifting back and forth to compensate.

Reasons to Choose a Regulator Valve

As mentioned, if your application requires consistent and precise flow and PSI for misting sprayers, pest control, disinfection sprayers, and the like, you'll want a pump with a regulator valve. They're also great for applications with low flow rates. Additional reasons to use a regulator valve are:

  • Simplicity of design for lower maintenance
  • Use of a DC motor with shorter bypass times 
  • Strong chemical use

Reasons to Choose an Unloader Valve

Applications requiring high PSI and flow rates are ideal for unloader valves because they allow for more starts and stops without overheating. Additional considerations and applications include:

  • Use of motor with longer bypass times
  • Energy-sensitive applications
  • Not concerned with ultra-precise spray patterns

Many find it confusing to decide whether to use an unloader or regulator in their equipment, especially if there's uncertainty over the anticipated flow rates and PSI. Checking out our Guide to Proper GPM and PSI below might help clear things up. You're also welcome to reach out to our team of pump experts to talk through your unique application. We're happy to help you determine the right kind of valve and pump that will deliver the results you need.

For more information, please visit unloading valve in hydraulic system.

CHAPTER 9: Relief and Unloading Pressure Controls

Pressure-control valves

Several types of pressure-control valves are found in fluid power circuits. Some keep the whole system from excess pressure while others only protect a portion of the system. Others allow flow to an isolated circuit after reaching a preset pressure. Some bypass fluid at low or no pressure when activated.

This chapter only covers relief valves and unloading valves because they are closely associated with hydraulic pumps. The other pressure-control valves are part of the control circuit and will be dealt with after directional control valves.

Why relief valves?

All fixed-volume pump circuits require a relief valve to protect the system from excess pressure. Fixed-volume pumps must move fluid when they turn. When a pump is unloading through an open-center circuit or actuators are in motion, fluid movement is not a problem. It is when the actuators stall with the directional valve still shifted that a relief valve is essential.

Pressure compensated pump circuits could run successfully without relief valves because they only move fluid when pressure drops below their compensator setting. (Most designers still use a relief valve in these circuits for reasons explained later.)

In either case, a relief valve is similar to a fuse in an electrical system. When circuit amperage stays below the fuse amperage, all is well. When circuit amperage tries to exceed fuse amperage, the fuse blows and disables the circuit. Both devices protect the system from excess pressure by keeping it below a preset level.

The difference is that when an electrical fuse blows it must be reset or replaced by maintenance personnel before the machine can cycle again. This requirement alerts the electricians to a possible problem and usually causes them to look for the reason before restarting the machine. Without the protection of a fuse, the electrical circuit would finally overheat and start a fire.

In a hydraulic circuit, a relief valve opens and bypasses fluid when pressure exceeds its setting. The valve then closes again when pressure falls. This means a relief valve can bypass fluid anytime . . . or all the time . . . without intervention by maintenance. (It also means the system can run hot even with a heat exchanger installed.)

Many fixed-volume pump circuits depend on this bypassing capability during the cycle, and some even bypass fluid during idle time. A well-designed circuit never bypasses fluid unless there is a malfunction, such as a control switch not closing or an operator overriding the controls. This eliminates most overheating problems and saves energy.

Relief valve operation

There are two different designs of relief valves in use: direct acting and pilot operated. Both types have advantages and work better in certain applications.
Some terms relating to relief valves and their function are:
' Overshoot: The actual pressure reading when a relief valve first opens to bypass fluid. (It can be up to twice the actual pressure setting.)
' Hysteresis: The difference in pressure between when a relief valve starts letting some flow pass (cracking pressure) and when full flow is passing.
' Stability: The fluctuation of pressure as a relief valve is bypassing at set pressure.
' Reseat pressure: The pressure at which a relief valve closes after it has been bypassing.
' Pressure override: The difference in the pressure reading from the time a relief valve first opens (cracking pressure) until it is passing all pump flow to tank.

Direct-acting relief valves

Figure 9-1 shows a cutaway view and the symbol for a direct-acting relief valve. The valve has a poppet that is pressed against its seat by an adjustable spring. An adjusting knob can be change the force on the spring to raise or lower maximum pressure. The poppet remains seated while pump flow goes to the circuit and pressure is lower than the relief valve setting. If pressure tries to go above spring setting, the poppet is forced off the seat just enough to pass excess pump flow to tank.

If you want to learn more, please visit our website 2-Way Hydraulic Solenoid Valve.