Glycol and Your Chilling System Explained

Glycol is a class of organic compounds that belong to the alcohol family. When mixed with water and pumped through the pipes of a chilling system, glycol serves to slow the rate of freezing. It helps maintain temperature consistency in the application. Some glycol products also work to inhibit corrosion and bacterial growth within the pipes of the chilling system.

The Two Types of Glycol Compared

Glycol comes in two varieties that should never be mixed together: ethylene glycol and propylene glycol.  Both types offer the same relative level of freeze protection. Both also help to guard against corrosion.  Some grades of both types of glycol also help to prevent the growth of algae and bacteria within the chiller.

Ethylene Glycol

Ethylene glycol is a moderately toxic chemical that has a sweet taste and can be harmful if swallowed. For this reason, it should not be used in potable water or

Propylene Glycol

Propylene glycol has a lower level of toxicity and is considered to be a food grade antifreeze.  This type of glycol is safer to handle than ethylene and can be more easily disposed of. 

Mixing Water with Glycol in Your Industrial Refrigeration System

Although you should never mix glycol types there is something that should always be added: water. As mentioned, glycol must be mixed with water to function properly. The type and amount of water to use are key factors to consider.

Type of Water to Use

Each glycol chiller comes with its own set of manufacturer recommendations for the best type of water to use for that system. Although city water may be acceptable initially, it is almost never recommended that de-ionized water be maintained for the long term as it could have adverse affects on certain metals in the chiller. Sometimes manufactures require the chiller to use distilled or reverse-osmosis water. The key is to check with the manufacturer for the particular needs of your refrigeration system. Read more about

Ratio of Water to Glycol to Use

Calculating the proper ratio of glycol to water in your chilling system depends on the coldest temperature that the glycol solution will reach during operation. If a chilling system is used indoors where there is no chance of freezing, the amount of glycol needed would be significantly less than required by a glycol chiller used outdoors where temperatures are prone to drop below freezing. Also, if an application requires a very low temperature to operate it should use a glycol mixture similar to that of an outdoor system. In a chilling system, this temperature is normally the saturated suction temperature in the evaporator, and normally this temperature is 10°F below the chiller set point temperature. Using the proper ratio of glycol and water in your chilling system is very important. Adding too much to your chiller system will cause it to become inefficient. However, not enough glycol could cause the system to freeze up, potentially bursting pipes or even rupturing the chiller evaporator.

Learn More About Glycol Chilling Systems

To learn more about how a glycol chiller works or to find out if this system is right for your application,

Berg manufactures glycol chilling systems for a wide variety of industries ranging from food and beverage processing to. Yet, what makes these systems unique and how they operate remains a mystery to many of our current and potential clients. Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system. Here are the top three things you should know about glycol chillers.Glycol is a class of organic compounds that belong to the alcohol family. When mixed with water and pumped through the pipes of a chilling system, glycol serves to slow the rate of freezing. It helps maintain temperature consistency in the application. Some glycol products also work to inhibit corrosion and bacterial growth within the pipes of the chilling system.Glycol comes in two varieties that should never be mixed together: ethylene glycol and propylene glycol. Both types offer the same relative level of freeze protection. Both also help to guard against corrosion. Some grades of both types of glycol also help to prevent the growth of algae and bacteria within the chiller.Ethylene glycol is a moderately toxic chemical that has a sweet taste and can be harmful if swallowed. For this reason, it should not be used in potable water ors when leakage is a possibility. Ethylene glycol has more widespread use due to its lower purchase price. Industrial applications likeandrequiring large volumes of the coolant find this to be the most economical choice of glycol.Propylene glycol has a lower level of toxicity and is considered to be a food grade antifreeze. This type of glycol is safer to handle than ethylene and can be more easily disposed of. Propylene glycol is commonly used inor in industrial refrigeration systems where people may come into contact with fluid. Propylene glycol can also become more viscous than ethylene, even slightly affecting the heat exchange rate when used at very low temperatures. It is important to note that you should never mix different types or brand names of glycol, as this leads to the product congealing and the clogging of filters in the refrigeration system 'potentially causing problems with heat transfer and fluid flow.Although you should never mix glycol types there is something that should always be added: water. As mentioned, glycol must be mixed with water to function properly. The type and amount of water to use are key factors to consider.Each glycol chiller comes with its own set of manufacturer recommendations for the best type of water to use for that system. Although city water may be acceptable initially, it is almost never recommended that de-ionized water be maintained for the long term as it could have adverse affects on certain metals in the chiller. Sometimes manufactures require the chiller to use distilled or reverse-osmosis water. The key is to check with the manufacturer for the particular needs of your refrigeration system. Read more about how process water can affect a chilling system's performance Calculating the proper ratio of glycol to water in your chilling system depends on the coldest temperature that the glycol solution will reach during operation. If a chilling system is used indoors where there is no chance of freezing, the amount of glycol needed would be significantly less than required by a glycol chiller used outdoors where temperatures are prone to drop below freezing. Also, if an application requires a very low temperature to operate it should use a glycol mixture similar to that of an outdoor system. In a chilling system, this temperature is normally the saturated suction temperature in the evaporator, and normally this temperature is 10°F below the chiller set point temperature. Using the proper ratio of glycol and water in your chilling system is very important. Adding too much to your chiller system will cause it to become inefficient. However, not enough glycol could cause the system to freeze up, potentially bursting pipes or even rupturing the chiller evaporator.To learn more about how a glycol chiller works or to find out if this system is right for your application,

Types, Uses, and Benefits of Glycol Chillers

Glycol Chillers

Please fill out the following form to submit a Request for Quote to any of the following companies listed on



Introduction

Here is the most complete guide on the internet about
You will learn:

This article takes an in depth look at glycol chillers.

You will learn more about topics such as:

  • What is a Glycol Chiller
  • Types of Glycol Chillers
  • Benefits of Glycol Chillers
  • The Design of Glycol Chillers
  • And much more '

Chapter One ' What is a Glycol Chiller?

A glycol chiller is an industrial cooling system that utilizes a mixture of glycol and water to achieve temperatures significantly below the freezing point of water. Glycol types used are either ethylene glycol or propylene glycol. The antifreeze properties of glycol help maintain the coolant in a liquid state at these low temperatures. Typically, the mixture consists of 60% glycol and 40% water in most chiller systems.


Increasing the concentration of glycol in the mixture enhances its antifreeze properties, which is particularly beneficial for achieving rapid cooling. This improvement in heat transfer efficiency is crucial for maintaining precise temperatures, which is often essential for the success of specific production processes.

Glycol-based industrial chillers circulate a glycol-water coolant through heat exchanger systems, where the coolant absorbs heat from industrial applications. The heated coolant is then processed through the chiller, where it is cooled down before being recirculated to absorb additional heat from various industrial processes. Glycol chillers are widely utilized due to their reliable performance in preserving frozen foods and supporting food production processes.

Chapter Two ' What are the different types of glycol industrial chillers?

Glycol, an organic alcohol compound, is commonly known for its antifreeze properties. Its key feature is its superior ability to transfer heat, which makes it particularly effective for cooling and chilling applications. Glycol mixtures in industrial chillers are adept at rapidly removing substantial amounts of heat, which is essential for maintaining reaction stability during chemical processes. Due to their rapid heat transfer capabilities, glycol chillers are crucial in scenarios where quick temperature control is necessary.

There are two primary types of glycol chillers: ethylene glycol and propylene glycol. Despite both being glycol compounds, they should not be mixed due to their distinct properties related to fluid characteristics, toxicity, and heat transfer efficiency. Mixing them could lead to system malfunctions or inefficiencies.

Ethylene and Propylene Chillers

Ethylene (EG) Glycol

Ethylene glycol serves as an antifreeze in industrial cooling systems, offering protection against freezing and acting as a rust inhibitor. The concentration of ethylene glycol in a water mixture is based on the lowest expected outdoor temperatures and the specific temperature requirements of the application. With a high flashpoint of 240°F, ethylene glycol is suitable for various industrial processes. However, its toxicity prevents its use in food processing applications.


Propylene (PG) Glycol

Propylene glycol, known for its low toxicity, is a food-grade antifreeze often used in environments where safety is a priority. It is more environmentally friendly than ethylene glycol and readily biodegradable. Propylene glycol chillers are suitable for use in the food industry and refrigeration systems where direct contact with the substance might occur. Despite being a synthetic compound, propylene glycol mixes well with water. The Food and Drug Administration has deemed it safe for use in maintaining moisture in medicines, cosmetics, and food products.


Glycol Industrial Chiller Types

Portable Glycol Industrial Chillers

Portable glycol chillers are small, compact, and self contained, with all of their components included in the unit. They have a capacity of 1 to 40 tons of cooling and are ideal for small loads or where special fluids, flows, pressure, or temperature are necessary. Due to the compact size of portable glycol industrial chillers, they can be used for test applications or positioned for temporary use.


Modular Glycol Industrial Chillers

A modular glycol industrial chiller system consists of multiple chillers connected to create a comprehensive cooling solution. This setup is highly adaptable, allowing for the addition of more chillers as demand grows. The system is designed to ensure uninterrupted cooling, even during maintenance periods.

Modular glycol industrial chillers feature oversized processing pumps and large glycol reservoirs with extra ports for system expansion. As new modules are added, the chilling capacity of the system increases significantly. This design is particularly advantageous for industries that cannot afford downtime, as it allows for backup chillers to take over if one unit fails.

One notable advantage of modular glycol industrial chiller systems is their ability to operate partially during periods of low heat load, which saves costs and enhances control. While the term "modular glycol industrial chiller" encompasses a broad range of designs, these systems are available in various configurations to suit different industrial needs.


Important Facts about Glycol Industrial Chillers

When selecting a glycol industrial chiller, several crucial factors must be taken into account. Their distinctive performance characteristics and high efficiency have made them a preferred choice for cooling critical production processes.

  1. The coolant in a glycol industrial chiller is a balanced mixture of glycol and water that is precision measured to achieve optimal results.
  2. Glycol is an organic compound from the alcohol family.
  3. The ratio of glycol to water is normally 60/40 but can be adjusted to meet the requirements of an application.
  4. As has been mentioned, there are two forms of glycol, which are ethylene and propylene with ethylene being toxic and propylene not being toxic.
  5. The use of a glycol chiller is ideal for food production.
  6. Problems that industrial equipment manufacturers work to avoid are corrosion, build up of algae, and the presence of bacteria. All glycol water coolants are resistant to the effects of corrosion as well as algae and bacteria.
  7. An essential part of all chiller functions is precision temperature control, which can be easily achieved with the use of a glycol industrial chiller due to its ability to have tight temperature controls.
  8. A side additive regarding the use of glycol chillers for food production is the enhancement of the taste and quality of the food produced.
  9. Although many chillers can reach exceptionally low temperatures, they are inhibited by several factors related to the coolant they use. Such constrictions are not found with glycol industrial chillers that can reach the lowest possible temperatures to meet the demands of any application.
  10. In the 21st century, protection of the environment and efficiency have become central focuses for industrial operations. To meet those demands, glycol industrial chillers are engineered, designed, and configured with various cost saving and environmental saving features.

Leading Manufacturers and Suppliers

    Chapter Three ' What is the design process for glycol industrial chillers?

    Process cooling systems are crucial for industrial applications, where heat accumulates during material blending, mixing, or chemical reactions. A cooling system helps maintain stable temperatures, allowing other manufacturing processes to proceed efficiently.

    One significant advantage of a glycol industrial chiller is its precise temperature control. Glycol's antifreeze properties prevent pipes from freezing, with both ethylene and propylene glycol being suitable for cooling systems but not interchangeable due to their differing properties.

    Glycol is an effective additive in cooling systems because of its compatibility with water. While the freezing point of water is 32°F, which can hinder or damage a cooling system, glycol lowers the freezing point to '60°F, enhancing the system's operational temperature range.

    The lower temperatures achievable with glycol allow a cooling system to remain effective longer than with water alone. These benefits have made glycol a crucial component in modern cooling systems.

    Glycol Industrial Chiller Design

    Closed Loop Design

    Glycol industrial chillers operate as closed-loop systems, where the coolant continuously circulates without exposure to the environment. This closed system keeps the glycol coolant clean and uncontaminated, preventing fouling or scaling and eliminating water loss from evaporation. As a result, closed-loop systems are exceptionally efficient and durable.

    Closed-loop systems also require less pumping power, which helps lower installation costs. The glycol coolant is circulated through tubing connected to the input and output sections of the chiller.

    Heat Exchangers ' Evaporator

    The heat exchanger allows the transfer of heat between the glycol water coolant and the refrigerant gas. It uses the flowing glycol to collect heat from the refrigerant and move the heat away from the area being cooled. The heat exchanger and glycol pipes are small since glycol is capable of removing more heat.


    Glycol Chiller Pump

    The low viscosity of glycol is why high-powered pumps are not required for operating a glycol chiller. Small pumps are essential for circulating the glycol and maintaining a consistent cool temperature. Depending on the chiller unit's design and the application's needs, the cooling system may require multiple pumps.


    Compressor for a Glycol Industrial Chiller

    The compressor takes low pressure and temperature refrigerant and compresses it into high pressure and temperature. There are several different types of compressors that a glycol industrial chiller can use with ones designed to fit the needs of the chiller and the applications for which it was developed. The different types of compressors include positive displacement, screw, diaphragm, screw, diaphragm, rotary, and centrifugal.


    Condenser in a Industrial Chiller

    The condenser absorbs the excess heat from the chiller's compressor, which it has received from the evaporator. This heat is transferred to water circulating around the condenser, which then releases the heat into the surrounding air.

    Water in the Chiller

    Water plays a crucial role in glycol systems, as glycol must be mixed with water for the system to function effectively. Key factors in the process include the type and quantity of water used, which can vary. Although city water can be used in a glycol industrial chiller, it is generally not recommended.

    Manufacturers recommend the use of distilled or reverse osmosis water to mix with glycol. Deionized water can initiate the chiller process but should be replaced since it can attack metals in the chiller and damage other components. Reverse osmosis or hyperfiltration removes contaminants through the use of pressure that forces water through a semipermeable membrane. The process can be seen below.

    The company is the world’s best Glycol for Chillers supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.


    Ratio of Water to Glycol

    Several factors must be considered when determining the ratio of water to glycol. The primary consideration is the location of the chiller and the ambient temperature of the environment. Indoor chillers, which are less likely to experience freezing conditions, typically require less glycol.

    For systems operating at very low temperatures, such as below 20°F, the glycol-to-water mixture should be adjusted similarly to that of an outdoor chiller system, corresponding to the saturated suction temperature in the evaporator or 10°F below the chiller's setpoint temperature.

    Determining the correct ratio of water to glycol depends on the coldest temperature the glycol system will encounter during operation. It is crucial to get this ratio right, as excessive glycol can lead to inefficiency, while insufficient glycol can cause the system to freeze or burst pipes.

    Once the appropriate type of water and glycol are selected, the chart below provides an approximate percentage of water to glycol for both outdoor and indoor glycol chiller applications.

    Glycol Chiller Applications Applications Percent of Water to Glycol Freeze Protection Burst Protection Indoor 30% to 70% 5°F or -15°C -20°F / -29°C Outdoor 50% to 50% -35°F or -37°C -60°F / -60°C

    Glycol Chiller Filtration

    Maintaining clean water and proper glycol content are critical factors in regard to the life of the cooling system as well as an important part of reducing downtime. To keep the water and glycol free of suspended solids, it is important to have a filtration system as part of the chiller.

    Automatic self-cleaning screen filters act as a barrier to suspended solids and are energy-efficient, although they can result in some coolant loss.

    A commonly used filtration method for glycol chillers is the side stream filter. This system removes a portion of the fluid flow to filter out solids and contaminants before returning the cleaned fluids to the system. Side stream filtration is effective in controlling suspended solids and helps maintain the integrity of the glycol and water mixture.


    Chapter Four ' What are the benefits of using glycol industrial chillers?

    Glycol industrial chillers are highly regarded for their efficiency in cooling systems, thanks to the precision control they offer and the low temperatures they can achieve. They are commonly used in beverage production, where maintaining specific cooling levels is crucial for ensuring the quality of the final product.

    Maintaining products at a consistently low temperature can be costly and necessitate frequent monitoring. The introduction of glycol systems in various sizes has streamlined the process, making it more affordable to produce high-quality products without the need for constant oversight of the cooling process.

    Glycol Chiller Benefits

    Safety Advantage

    A common concern with refrigeration systems is the risk of leaks that can lead to temperature increases and potential crop damage. This issue is mitigated with glycol chillers, as glycol contains inhibitors that make the system resistant to corrosion, scaling, and rust, thereby reducing the likelihood of leaks and damage to pipes.

    Propylene or ethylene glycol acts as an anti-freeze, preventing freezing inside the coils. The glycol and water mixture also helps protect the chiller from the buildup of algae and bacteria.

    Industrial Chiller Maintenance

    Another safety feature of glycol chillers is their low maintenance requirements. These chillers can store and keep products cool for extended periods without the need for expensive upkeep. They are designed to last for years, delivering exceptional performance with minimal maintenance needs.

    Glycol Chiller Pipes

    Glycol industrial chiller pipes are capable of running longer distances, servicing multiple processing locations from a single cooler and pump package. These pipes come in various types, with PVC80 being a common choice. Proper installation is crucial, and using a reverse return method helps balance the flow across the equipment by ensuring that the cooling medium travels the same distance to and from the chiller. The size of the piping is determined by the flow requirements of the equipment, considering factors like pressure drop and velocity.

    Economizer Feature

    The economizer feature in glycol industrial chillers leverages cold ambient air for cooling when the temperature is suitable. A control switch deactivates the compressor and utilizes the chilled environmental air to meet the thermostat's setpoint. This feature enhances efficiency and reduces operating costs by integrating ambient air into the cooling process.

    Low Temperatures

    Glycol industrial chillers can operate at temperatures well below the freezing point of water, with control over these temperatures achieved by adjusting the glycol mixture percentages. For example, a 10% ethylene glycol mixture freezes at 26°F, whereas a 60% mixture freezes at -60°F. Glycol's antifreeze properties ensure that the coolant remains in a fluid state, even at extremely low temperatures.

    Cost Savings

    Opting for a glycol industrial chiller can be significantly more cost-effective compared to multiple self-contained refrigeration units. A single glycol chiller unit, which includes a chiller compressor to cool the glycol and water, often costs less than half of what it would cost to purchase several separate refrigeration units.

    Chapter Five ' What are the common uses for glycol chillers?

    Over the years, cooling systems have evolved significantly, moving away from outdated and harmful methods. The chiller manufacturing industry has become more environmentally conscious, developing cooling solutions that comply with environmental agency regulations.

    These advancements in cooling technology have expanded their use across various industries and provided solutions for applications that previously lacked effective cooling options. A key aspect of this progress is the incorporation of glycol as an additive in cooling systems, which has enhanced their efficiency and versatility.

    Industrial Glycol Chiller Uses

    Grocery Store Display Cases

    With increasing environmental safety restrictions, grocery stores need chilling units that meet eco-requirements while providing long-lasting and durable solutions. Propylene glycol industrial chillers, which are food grade, are ideal for frozen food chiller cases. They are specifically engineered to efficiently remove heat while being robust enough to withstand constant use.


    Produce Packing

    Maintaining the freshness of fruits and vegetables is crucial in the produce packing industry. Failures, downtimes, and maintenance delays can ruin a shipment of products. Like grocery stores, cooling units must comply with food grade requirements while being robust enough for continuous use. Propylene glycol industrial chillers are engineered to meet the stringent demands of the produce shipping industry, making them an ideal choice for ensuring reliable and effective cooling.

    Glycol and Breweries

    One of the areas where glycol industrial chillers are used the most is the brewing industry, which requires precisely controlled temperatures and conditions. The maintenance of temperature has to be consistent since any fluctuations can have extremely negative effects on the quality of the final product. It is for these reasons that propylene glycol industrial chillers help to precisely regulate and maintain container temperatures.


    Ice Rink

    Engineering an outdoor ice rink in a warm climate presents unique challenges. However, glycol chillers, which can cool below the freezing point of water, make it feasible. In such installations, glycol is pumped through mats placed beneath the ice rink surface. Water sprayed over these mats then freezes upon contact, allowing the rink to maintain ice even in warmer temperatures.


    Dairy Products

    Similar to breweries, the quality of dairy products heavily depends on an effective cooling system, as inadequate or unsuitable systems can lead to bacterial growth. Consistent temperature control throughout the dairy manufacturing process is essential. Milk is pumped directly from cows into cooling units, which store it until further processing.

    Maintaining a stable temperature at every stage of the process is crucial to prevent spoilage and bacterial growth in raw milk.


    The few examples of glycol chiller applications provided are just a fraction of their extensive uses. Any industry where heat is a factor in the process relies on glycol chillers to effectively remove and dissipate heat.

    Chapter Six ' What are some tips for using industrial glycol chillers effectively?

    There are specific actions and considerations to avoid in order to keep a glycol chiller operating at peak performance. Failing to follow these guidelines can result in damage or complete system failure. Glycol chiller manufacturers provide clients with essential information during installation to ensure the system performs optimally.

    Glycol Industrial Chiller Maintenance Tips

    Automotive Antifreeze

    While automotive antifreeze contains similar chemicals to glycol coolants used in chillers, it is formulated differently. Using automotive antifreeze can lead to reduced flow rates, pressure issues, and a significant decrease in heat transfer efficiency.

    Inhibited Glycol

    Inhibited glycol contains additives that protect against corrosion, scale, and rust, unlike uninhibited glycol. For effective protection, glycol must be used in concentrations of 25% or higher to ensure that the inhibitors are present in sufficient quantities.

    Mixing Ethylene and Propylene Glycol

    Manufacturers strongly advise against mixing ethylene and propylene glycol or different brands of glycol. The incompatibility of various formulations can result in clogged filters, strainers, and pumps, as well as problems with transfer properties.

    Local Regulations

    Different states, counties, and cities have varying regulations regarding the use of glycol and antifreeze to protect water tables, drainage systems, and fluid disposal. It is crucial to check with local authorities before installing a glycol chiller to ensure compliance with municipal regulations.

    Contamination

    The ratio of glycol to water must be regularly checked and tested to maintain the correct percentages and prevent corrosion issues.

    Pure Water

    Glycol chillers perform best when using distilled or reverse osmosis purified water, as city water often contains contaminants that can interfere with the glycol-water mixture. Other pure water options include demineralized water, which eliminates the unpredictability associated with municipal water.

    Conclusion

    • A glycol industrial chiller is a chilling system that uses a percentage of glycol mixed with water to create extremely low temperatures far beyond the freezing point of water.
    • By increasing the percentage of glycol, the antifreeze properties of the mixture are significantly improved, which is useful when rapid cooling is necessary.
    • There are two types of glycol industrial chillers, which are ethylene and propylene. Though both are glycol compounds, they cannot be mixed because they have different fluid, toxicity, and heat transfer properties that would prevent a system from working properly.
    • Process cooling systems are essential to industrial applications since heat energy builds up when materials are blended and mixed or where chemicals are combined. The use of a cooling system assists in holding materials at a stable temperature, which allows other manufacturing operations to continue.
    • The lower temperatures achieved through the use of glycol allows a cooling system to remain cooled and chilled longer than is possible using water alone. The additional benefits of glycol have made it an essential part of modern cooling systems.

    Leading Manufacturers and Suppliers

      If you are looking for more details, kindly visit Glycol in Water System.