Cooling towers are recirculating water systems used to remove heat from building air conditioning equipment and industrial processes. They require specialized maintenance to ensure safe, efficient, and reliable operation, including an effective water treatment program. By understanding how cooling tower systems function, facility owners and operators can operate and maintain their systems more effectively.
If you are looking for more details, kindly visit cooling tower hamon.
Cooling tower systems work by using water to extract waste heat from a system and ejecting it into the atmosphere primarily through evaporation. The three key components of a cooling system are the cooling tower, recirculating pump, and heat exchanger. Water first passes through a heat exchanger where it absorbs heat. The water is then distributed over the top of the cooling tower where air travels past the warm water causing a portion of the water to evaporate. The heat is transferred from the water stream to the air stream, raising the air's temperature and its relative humidity to 100%. This warm air is then discharged to the atmosphere, resulting in a cool water stream. The cooled water from the basin is then pumped back through a heat exchanger and the cycle repeats.
Evaporative heat-rejection devices such as cooling towers provide significantly lower water temperatures than those achievable with air cooled or dry heat rejection devices, thereby achieving a more cost-effective and energy-efficient cooling system. Cooling towers save a lot of water and energy versus air-cooled HVAC or process cooling systems. For example, it can take 50% more electricity to operate a 400-ton air-cooled chiller than it does a 400-ton water-cooled chiller. With the proper cooling system programs in place, building HVAC, cold storage, and industrial cooling systems can be optimized for the most efficient output while minimizing operating costs.
Cooling towers require proper maintenance to ensure the most efficient operation and to reduce downtime. There are several cooling tower challenges: water conservation, corrosion, scale, deposits, and microbiological activity. Evaporated water leaves behind dissolved impurities from the makeup water which can become concentrated leading to scale, deposits, and corrosion. These issues can cause water equipment failure leading to production downtime, added costs, and reduced efficiency. Professional water treatment minimizes these challenges by expert support, focused optimization, and industry best practices.
Chem-Aqua is an industry leader in providing custom water treatment solutions for a variety of applications and industries. We specialize in providing custom-designed water treatment programs for boiler, cooling, and process water systems. Chem-Aqua solutions are designed to minimize their customer’s energy, water, and maintenance costs while ensuring safe and reliable operation of these critical systems. Our water treatment programs for cooling towers are engineered to minimize corrosion, scale, microbiological activity, water usage, and energy usage.
To drastically reduce your cooling systems operating costs, increase cooling efficiency, and minimize the operation challenges of your cooling towers, contact us today!
In this topic, we will look at how a cooling tower operates. This will cover the basic workings of the most common type of cooling tower “wet” or “open” which you will find on most commercial high rise and industrial sites.
Open or wet cooling towers are the most efficient way to reject heat from the cooling system because the water evaporates to carry the heat away. This results in a loss of water from the cooling system and so it is not suitable for all locations and system designs.
Consider the cooling tower on top of a typical office type building. A centrifugal pump moves water, known as “condenser water”, between the chiller in the basement and the cooling tower on the roof. The chiller adds heat to the condenser water and the cooling tower cools it down by rejecting this into the atmosphere. The heat it rejects is all the unwanted heat from the building caused by the people, computers, sunlight, lighting etc. It must also reject the heat generated by the compressor of the chiller.
The condenser water leaves the condenser of the chiller at around 32°C (89.6°F) and the pump sends this up to the cooling tower. The system has been designed so that the condenser water leaving the cooling tower and re-entering the chiller condenser, must be around 27°C (80.6°F) in order to be able to pickup enough heat on it’s next cycle.
Before we look at how a cooling tower rejects heat. Let’s first look at the parts inside a cooling tower.
Parts Of A Cooling TowerFan: The fan pulls cool ambient air in through the filters at the base and pushes it out the top of the cooling tower, taking heat and moisture with it.
Drive Belt and Drive Motor: The simplest method of spinning the fan blades. It could also be direct drive, chain driven or gear mounted.
Drift Eliminator: This causes the air to change direction and condense some of the moisture in the leaving air which reduce operating costs.
Condenser Water Inlet: This is where the warm condenser water enters the cooling tower
Spray Nozzles: The warm condenser water is pushed through these nozzles, causing it to spilt into a spray of small droplets.
Fill Packaging: The condenser water spray droplets run down this increasing the heat transfer surface area and allowing the air (which flows in the opposite direction) to carry some of the heat away as well as moisture from the evaporation.
Filter: This is where the fan pulls it’s air in from. The filter limits the amount of dirt and leafs entering the cooling tower. Air enters cooler and dryer here then when it leaves at the top.
Condenser Water Outlet: This is where the condenser water will leave the cooling tower. It will leave at a lower temperature than when it entered at the top.
For more information, please visit nihon spindle cooling tower.
Makeup Water: A minimum water level is held in the basin of the cooling tower. Water is lost from the cooling tower from evaporation but also when the cooling tower drains to get rid of accumulated dirt and salt.
Overflow: If the water level in the basin gets too high, it will flow through here and out to a drain.
Drain: Water will be drained from the cooling tower for maintenance purposes but also periodically during normal operation when the level of impurities in the water gets too high. The impurities are from the accumulation of dirt and salts which build up as water evaporates and leaves these behind. This is often reffed to to “blowdown”.
The warm condenser water enters near the top of the cooling tower. It passes through some nozzles which spray the water in small droplets across the fill packaging. The spray increases the waters surface area which allows it to reject more heat.
Cooling Tower spray nozzlesCooling Tower fill packagingThe water is sprayed across the fill packaging
Condenser water spray on to fill packagingThese droplets, from the spray, run down the fill packaging causing a thin film of water on its surface. The water will evaporate into the air and carry heat away with it.
Thin film of condenser waterFor greater cooling capacity, cooling towers use a fan to create more evaporation. The fan pulls air through the filters at the bottom of the unit and move it up and out through the top of the cooling tower, passing through the fill packaging and drift eliminators. The air flows in the opposite direction to the flow of condenser water.
Cooling tower air flowing past fill packagingCombining the spray of water, the thin film of water on the fill packaging and the flow of cool air you get a great amount of heat transfer.
Flow of air and condenser waterJust to recap. Warm condenser water enters the tower and is sprayed over the fill packaging. This spray runs down the fill packaging creating a thin film of water over it, the water will evaporate and cool down. Cool dry air enters through the bottom of the tower and passes through the fill packaging in the opposite direction to the flow of condenser water, this will pickup heat and moisture from the thin film of water. The condenser water will leave the bottom of the cooling tower at a lower temperature. The air will leave the top of the cooling tower with that heat but it will also carry some of the water away with it.
Cooling Tower heat transferWater costs money. So in order to keep operating costs and water consumption down, cooling towers often use drift eliminators. These are located above the fill packaging and spray nozzles but below the fan.
Cooling Tower drift eliminatorsThe drift eliminators purposely change direction to cause the leaving air to condense against the sides. This squeezes some of the moisture out of the air which then runs back down to the fill packaging for further cooling and eventually accumulates in the basin of the cooling tower to be sent back to the chiller.
Drift eliminator on a cooling towerThe cooler condenser water accumulates in the basin of the tower. This returns to the chiller where it will pickup more heat and the cycle starts over again. A filter is usually present over the outlet to ensure no foreign objects enter the pipe as this will enter the blades of the pump.
Cooling Tower BasinA float valve in the basin operates the flow of water from the makeup water inlet and ensures a minimum level of water is maintained. This water is topped up because of evaporation losses and also during blow downs.
The overflow prevents too much condenser water entering the cooling tower basin. Water entering here will usually be sent to drain.
The drain usually has an automated valve attached. Sensors located in the basin or the condenser system pipework will detect the level of impurities (dirt and salts) and will start to drain the water if the level is too high. This draining is known as the “blowdown” and causes the float valve to drop which allows fresh water to enter through the makeup inlet. The impurities are already in the condenser water as well as the air, but as the water evaporates it leaves these behind. If enough water evaporates it will cause a build up of impurities which can damage the equipment as well as reduce the cooling tower, chiller and pump effectiveness and efficiency.
In cooler climates, some cooling tower basins will have an electric pan heater installed. This turns on at a specified minimum air temperature (e.g. 5°C, 41°F) to prevent frost.
Watch the video tutorials below for further information.
If you want to learn more, please visit our website marley 300 ton cooling tower.